diff --git a/config/power-meters.example.yaml b/config/power-meters.example.yaml index ae450e7..65fa968 100644 --- a/config/power-meters.example.yaml +++ b/config/power-meters.example.yaml @@ -12,6 +12,8 @@ meters: # L1: # L3: phase_active_power: + L1: 4d94a3f2-005d-4132-9b44-b8ae1d9fa174 L2: d9ae584e-551b-44b8-a822-3cf9554e77e4 + L3: 16fadb64-66b2-46e1-b94e-52499d607dbc poll_interval_seconds: 60 report_mount_path: /mnt/reports/energy diff --git a/docs/enlyze-api.md b/docs/enlyze-api.md index d8ec04d..9b09973 100644 --- a/docs/enlyze-api.md +++ b/docs/enlyze-api.md @@ -102,6 +102,31 @@ an approximate reported finished-product mass of 4,845.8 kg. This supports the physical plausibility of the feed integration; it is not a precise material yield calculation. +### B2 power-meter signals + +Verified B2 machine UUID: `0d7955e9-5cde-4e14-9af7-5b041dc796f0`. +These are customer-specific observations. + +| B2 signal | Verified ENLYZE UUID | Register | +| --- | --- | --- | +| L2 active power | `d9ae584e-551b-44b8-a822-3cf9554e77e4` | `3055` | +| Power Outages | `ea1f1f51-1758-4818-8ec3-fbb4b76d1a77` | `1828` | + +Other verified configured signals are total energy +`0f5c0853-1aa7-4fa3-b267-ea2669024e46`, total active power +`41e5729e-b724-49d4-ad24-666d959e121d`, and grid frequency +`127ddf56-9358-43ce-84fe-f7631486cfc9`. + +As of 2026-10-01, the collector is running for B2 with total active power, +L2 active power, total energy, grid frequency, and Power Outages +(operator-confirmed production state; sandbox systemd access cannot independently +confirm live status). Both additional signals are verified and configured. + +The deployed service is `production-analytics-power-meter.service`. See the +[production runbook](../README.md#production-service-and-runtime-settings) for +`.env`/secret-file requirements and start/restart/status/log commands. +**The SMB report mount at `/mnt/reports/energy` is still pending.** + ## STILL UNKNOWN - Full customer response coverage, permissions, authentication diff --git a/tests/test_power_meter.py b/tests/test_power_meter.py index 509f3ab..17150c9 100644 --- a/tests/test_power_meter.py +++ b/tests/test_power_meter.py @@ -12,7 +12,8 @@ def test_b2_config_has_only_verified_signals() -> None: config = load_power_meter_config("config/power-meters.example.yaml", "B2") assert config.machine_uuid == "0d7955e9-5cde-4e14-9af7-5b041dc796f0" assert config.signals.energy_total == "0f5c0853-1aa7-4fa3-b267-ea2669024e46" - assert config.signals.power_outages is None + assert config.signals.power_outages == "ea1f1f51-1758-4818-8ec3-fbb4b76d1a77" + assert dict(config.signals.phase_active_power)["L2"] == "d9ae584e-551b-44b8-a822-3cf9554e77e4" def test_counter_reset_starts_new_epoch() -> None: