@@ -52,6 +52,9 @@ This is calculation-domain logic, with no ENLYZE transport dependency.
The detector uses timestamps rather than a sample count. An interval longer
than the configured positive `max_sample_gap_seconds` restarts a reset candidate,
so a timestamp alone does not establish that a signal was continuously below
threshold. Equal
timestamps are processed in arrival order but contribute no elapsed time, and
backwards timestamps are rejected. Reset values are not assumed to be zero.
threshold. These parameters (`min_peak`, `drop_ratio`, `hold_seconds`, and
`max_sample_gap_seconds`) are selected per signal rather than treated as global
process constants. Equal timestamps are processed in arrival order but
contribute no elapsed time, and backwards timestamps are rejected. Reset values
are not assumed to approach zero, and peak values may vary materially between
cycles.