# Shift running-speed KPI
`average_line_speed_m_min` is the arithmetic mean of finite speed samples
strictly above the configured production gate within `[start, end)`. Samples
have equal weight regardless of spacing. Inactive time does not contribute to
this KPI. No interpolation, carry-forward, or time weighting is applied.
`average_line_speed_m_min` is the arithmetic mean of active, finite production-speed
samples in `[start, end)`. Each active sample has equal weight. The calculation does
not interpolate or weight speed by elapsed time.
The immutable summary includes signal, unit, gate, window, finite sample count,
active/inactive counts, active average/minimum/maximum, and invalid sample count.
`sample_count` counts finite numeric in-window values and equals active plus
inactive counts. Zero, negative, and values equal to or below the gate are
inactive. Null, non-numeric, boolean, NaN, and infinite values are invalid and
excluded from all finite/active statistics. Invalid/missing timestamps are also
counted separately as unavailable because window membership cannot be verified.
Absent source rows are not synthesized or counted. Without active samples,
average, minimum, and maximum are all `None`.
## Activity gates
Window timestamps must be timezone aware and have positive elapsed duration.
All boundary comparisons use UTC instants, including DST folds.
The `speed` block has exactly one activity method:
## Configuration and service API
- **Simple numeric:** `production_gate_m_min` selects speed samples strictly above
the threshold. B1, E1 and K7 retain this behavior.
- **Boolean:** `running_signal_ref` and optional `running_when` (default `true`)
select samples whose status is exactly that Boolean. K5 uses `running_when: false`
because its status signal is true when stopped.
- **Numeric dwell:** `numeric_dwell_gate` has `signal_ref`, finite `threshold`,
`comparison` (`below` or `above`), and positive integer
`minimum_duration_seconds`. Gitter 1–4 use `below` and 150 seconds. Their
production-speed signal holds its last value while stopped, and their PLC
Boolean status did not reliably indicate downtime. The numeric gate follows
the configured ENLYZE threshold and minimum duration concept.
Machine-specific UUIDs, signal labels, units, and gates live in
`config/shift-report-machines.yaml`. It also contains the ERP workplace and material source references needed for
report composition; existing material-calculation definitions are not duplicated. The configured gates are
B1: 0.3 m/min; E1: 0.5 m/min; K7: 0.5 m/min. The config loader validates required
fields, non-empty identifiers, unique machine IDs, m/min units, and finite
non-negative gates. It returns frozen report machine configurations by name, each with a nested
`ShiftSpeedConfig` in `.speed`.
For `below`, only a gate value strictly less than the threshold satisfies the
condition. An equal value ends a below-threshold run. Rows are ordered by their
UTC timestamps; a condition reading remains the observed state until the next
reading. A continuous below-threshold run qualifies when the elapsed time from
its first below-threshold timestamp to the first non-below reading is at least
the minimum duration. If it qualifies, **all** speed samples in that run are
inactive, including those before the minimum duration elapsed. A short run
bracketed by non-below readings stays active. The same rules apply to `above`.
The interval ending at the non-satisfying reading excludes that reading.
```python
from datetime import datetime
from zoneinfo import ZoneInfo
The service requests speed and the gate signal together from `/v2/timeseries`.
For a dwell gate it extends the read window by one minimum duration on each side;
only production-speed samples in the original report window enter the KPI. This
lets a qualifying run crossing a report boundary be classified when the source
provides enough surrounding readings. An unclosed short run, or a short run
without a preceding non-satisfying reading, has unknown duration and is excluded
conservatively. An invalid or non-finite gate reading breaks continuity and its
speed row is excluded. A missing required gate column fails the read. No absent
rows are synthesized; the result depends on the timestamps returned by ENLYZE,
which deserves validation against live boundary cases.
from production_analytics.enlyze.gateway import EnlyzeApiGateway
from production_analytics.service.shift_report_config import load_shift_report_machines
from production_analytics.service.shift_speed import ShiftSpeedService
Invalid speed values (including Boolean, null, non-numeric, NaN, and infinity)
are excluded in every mode. Invalid timestamps are also excluded. In Boolean
mode, missing or non-Boolean status is excluded. `sample_count` is the sum of
active and inactive valid speed samples; excluded samples increment
`invalid_sample_count`. If no active samples remain, average, minimum and maximum
are `None`.
machines = load_shift_report_machines("config/shift-report-machines.yaml")
service = ShiftSpeedService(EnlyzeApiGateway(client)) # Existing ExplorationClient
summary = service.summarize(
config=machines["K7"].speed,
start=datetime(2026, 10, 7, 6, tzinfo=ZoneInfo("Europe/Berlin")),
end=datetime(2026, 10, 7, 14, tzinfo=ZoneInfo("Europe/Berlin")),
)
```
Machine UUIDs and gate settings live in `config/shift-report-machines.yaml`.
The loader validates the gate fields and rejects overlapping Boolean and dwell
gates. `ShiftSpeedService.summarize()` composes the gateway read with the pure
`aggregate_shift_speed()` calculation. The calculation accepts
`ShiftSpeedSample(timestamp, value, running, gate_value)` records. Structural
timeseries and pagination errors fail the read instead of returning a partial KPI.
`aggregate_shift_speed(samples, config=..., start=..., end=...)` is the pure
calculation API, accepting `ShiftSpeedSample(timestamp, value)` objects.
`EnlyzeApiGateway.get_speed_samples(machine_id=..., speed_signal_ref=...,
start=..., end=...)` requests just the configured signal from `/v2/timeseries`,
using the existing client and cursor semantics. It tolerates unavailable sample
values/timestamps; structural response and pagination errors fail the read,
preventing a partial successful summary. No snapshots are persisted.
## Supplied live reference
## Supplied legacy reference
For 2026-10-07 06:00–14:00 Europe/Berlin:
@@ -63,6 +65,4 @@ For 2026-10-07 06:00–14:00 Europe/Berlin:
| E1 | 2880 | 2782 | 7.933009468249328 |
| K7 | 2880 | 2667 | 10.078945039942955 |
These are the supplied validation values, not a new live read performed during
implementation. Tests cover filtering, statistics, boundary/DST behavior,
configuration, service composition, and gateway pagination with mocked responses.
These are supplied validation values, not a new live read.