Add central material calibration support

This commit is contained in:
2026-09-09 03:22:47 +02:00
parent 0210ced9e3
commit 73a6e60450
21 changed files with 848 additions and 23 deletions
+2 -1
View File
@@ -4,11 +4,12 @@ calculations:
type: material_consumption
version: "1"
machine_ref: 5f42a4f6-9ca0-4f6f-9786-40d50a35b230
process_application_calculation_id: bento1-fresh-bentonite-application
source_mode: rotational_discharge
rotational_speed_signal_refs:
- 6e5d2d94-98f9-4cc1-8a88-7987c6282525
- cd7385c4-337b-4759-ab32-45d65beaf190
specific_discharge_kg_per_rev_m: 3.12
calibration_ref: bento1-spreader-1-2
# Transport Auszug Geschwindigkeit Istwert, m/min (production gate only).
gate_signal_ref: fef41976-1103-4090-b780-eaeecc02fdfa
gate_threshold: 0.3
+7
View File
@@ -0,0 +1,7 @@
workplace: BENTO 1
machine_id: 5f42a4f6-9ca0-4f6f-9786-40d50a35b230
calculation_id: bento1-fresh-bentonite-consumption
output_calculation_id: bento1-fresh-bentonite-efficiency
production_order_format: "Bento 1-{production_order}"
erp_timezone: Europe/Berlin
poll_interval_seconds: 60
+14
View File
@@ -0,0 +1,14 @@
calibrations:
bento1-spreader-1-2:
type: rotational_discharge
value: 2.75
unit: kg_per_rev_m
calibrated_at: 2026-09-08
method: gravimetric_tray
description: Bento 1 fresh-bentonite spreaders 1 and 2
reference:
measured_application_g_m2: 4068
line_speed_m_min: 2.3
signal_values:
left: 1.65
right: 1.75