Add calibrated Bento spreader 3 consumption
This commit is contained in:
1 parent
7ff452d36c
commit
7ff3087775
12 files changed
+485
-31
No files matched your search
@@ -3,8 +3,7 @@
|
||||
|
||||
## Three distinct quantities
|
||||
|
||||
All **fresh bentonite** values exclude the third recycled/recovered-material
|
||||
scatterer. Only the two actual rpm signals listed below are used; no SET signals
|
||||
All **fresh bentonite** values exclude the separate spreader 3. Only the two actual rpm signals listed below are used; no SET signals
|
||||
are introduced. The specific discharge is central calibration
|
||||
data: **2.75 kg/(revolution × metre product width)**.
|
||||
|
||||
@@ -56,7 +55,7 @@ Scope Grafana queries by calculation ID and
|
||||
`material_snapshot_timestamp` for auditability.
|
||||
|
||||
`config/bento1-material-consumption.yaml` opts into process snapshots through
|
||||
`process_application_calculation_id`. This generic option requires rotational
|
||||
`process_application_calculation_id`. This generic option requires calibrated
|
||||
sources and a positive speed gate. Both outputs reuse the same configured ACT
|
||||
signals, discharge factor and samples. Process points use source timestamps,
|
||||
including bootstrap samples from disjoint runs; no interpolation or hold-forward
|
||||
@@ -103,7 +102,7 @@ cleanup was performed as part of this implementation.
|
||||
`config/bento1-material-consumption.yaml` defines
|
||||
`bento1-fresh-bentonite-consumption`, an estimate of **fresh bentonite consumption**
|
||||
from actual spreader roll speeds. Both needle rolls apply sequentially across the
|
||||
full web width. The recycled/recovered third spreader is excluded.
|
||||
full web width. Spreader 3 is excluded.
|
||||
|
||||
The generic `rotational_discharge` source converts one or more rpm signals to the
|
||||
existing integrator's kg/h: `sum(rpm) × nominal_width_m × specific_discharge_kg_per_rev_m × 60`.
|
||||
@@ -155,6 +154,83 @@ and persistence semantics.
|
||||
Tests use realistic rpm values and synthetic samples, including disjoint-run
|
||||
bootstrap and persisted resume. They are not a new replay of recorded ENLYZE data.
|
||||
|
||||
## Separate spreader 3 material source
|
||||
|
||||
Spreader 1+2 remains fresh bentonite from actual roll rpm, calibrated at
|
||||
**2.75 kg/(rev*m)**. Spreader 3 is a separate material source: it can contain
|
||||
bentonite or sand depending on the product. No material identity is inferred,
|
||||
and no spreader-3 value is added to fresh-bentonite consumption or efficiency.
|
||||
No total-bentonite aggregate or sand calibration is implemented.
|
||||
|
||||
`config/bento1-spreader3-material-consumption.yaml` uses generic
|
||||
`linear_signal_discharge` with central calibration
|
||||
`bento1-spreader-3-bentonite`: **0.4691089108910891 kg/(signal_unit*m)**,
|
||||
gravimetric tray, 2026-09-08. Reference: **3.03 signal @ 2.3 m/min → 618 g/m²**.
|
||||
The exact factor is `618 * 2.3 / (3.03 * 1000) = 2369/5050`; the supplied
|
||||
approximation 0.4693069307 differs from this measurement-derived value.
|
||||
Source `c5611859-275c-44c4-aec0-dfaccc87d478`, display name
|
||||
“Austragsbehälter Austragsschnecke Geschwindigkeit Istwert”, origin
|
||||
`AUFSTREUUNG_2/DischargeHopper_Output_Screw/ACT_Speed`.
|
||||
ENLYZE's kg/m² metadata is not used as physical truth. Observed values on
|
||||
2026-09-09 were around 3.0 during operation and 0.0 when inactive.
|
||||
|
||||
- Application: `signal_sum * factor * 1000 / line_speed_m_min`, independent of width.
|
||||
- Consumption rate: `signal_sum * factor * nominal_width_m` in kg/min,
|
||||
multiplied by 60 for the existing kg/h integrator. This equals
|
||||
`application_g_m2 * nominal_width_m * line_speed_m_min / 1000`.
|
||||
- Same ERP nominal-width provider, `Bento 1-{production_order}` formatting,
|
||||
gate signal `fef41976-1103-4090-b780-eaeecc02fdfa` strictly > 0.3 m/min,
|
||||
previous-value integration, 20-second maximum gap, and disjoint-run boundaries.
|
||||
- Application points are emitted only while the gate is active; zero source
|
||||
signal emits zero application during production.
|
||||
|
||||
| Calculation ID | Persistence |
|
||||
| --- | --- |
|
||||
| `bento1-spreader3-application` | `material_application_snapshots.application_g_m2` |
|
||||
| `bento1-spreader3-consumption` | `material_consumption_snapshots.consumption_kg` |
|
||||
|
||||
The new linear source namespaces JSON checkpoints under
|
||||
`<state-directory>/<sha256(consumption-calculation-id)>/`; existing 1+2 and K7
|
||||
checkpoint paths remain unchanged. Use a separate supervised consumption runner
|
||||
with the spreader-3 config. No schema changes are needed if the existing generic
|
||||
snapshot tables are present; otherwise apply `db/schema.sql` before starting it.
|
||||
Do not reset 1+2 state. No migration, deployment, or service restart was performed.
|
||||
|
||||
Production validation, 30 Sep 2026 10:00–13:00 Europe/Berlin, order `12026000984`,
|
||||
article `180205` (Bfix NSP 4900, 5,00 x 40 m): `8.999 @ 4.999 m/min` gives
|
||||
**844.471112 g/m²**. Adding the measured 1+2 average of 3915.961 gives
|
||||
**4760.432112 g/m²**, within the expected 4400–4800 range.
|
||||
|
||||
Before redeployment, stop the spreader 3 runner and back up its checkpoints and
|
||||
snapshots. Clear only its consumption checkpoint directory:
|
||||
`<state-directory>/c8d0426504f2ce2ff214818e4ffa9b4daf4182131c0af3c5a1cca23a3dee566a/`.
|
||||
With the default state root this is
|
||||
`/opt/git-projects/production-analytics/data/state/material/c8d0426504f2ce2ff214818e4ffa9b4daf4182131c0af3c5a1cca23a3dee566a/`.
|
||||
There is no separate application checkpoint directory. Clear all affected snapshot
|
||||
rows, across orders and timestamps, using these exact predicates:
|
||||
|
||||
```sql
|
||||
DELETE FROM material_application_snapshots
|
||||
WHERE calculation_id = 'bento1-spreader3-application'
|
||||
AND machine_id = '5f42a4f6-9ca0-4f6f-9786-40d50a35b230';
|
||||
DELETE FROM material_consumption_snapshots
|
||||
WHERE calculation_id = 'bento1-spreader3-consumption'
|
||||
AND machine_id = '5f42a4f6-9ca0-4f6f-9786-40d50a35b230';
|
||||
```
|
||||
|
||||
Perform cleanup before restarting with the corrected model; arrange a replay for
|
||||
historical orders if corrected history is needed. Snapshot writes use
|
||||
`ON CONFLICT DO NOTHING`, so existing application rows cannot correct themselves.
|
||||
Leave spreaders 1+2 and K7 checkpoints and snapshots intact. These are instructions
|
||||
only; no stored data has been deleted by this code change.
|
||||
|
||||
This calibration is valid only for bentonite. Enable this runner only for
|
||||
validated bentonite operation; until reliable material identification is available,
|
||||
its output is a bentonite-calibrated estimate, not material-aware consumption.
|
||||
Future sand support needs independently measured calibration and reliable
|
||||
material/order attribution, with explicit handling of material changes and
|
||||
checkpoint/history separation. Current ERP width is assumed constant per order.
|
||||
|
||||
## Historical migration from SET to rpm: review before execution
|
||||
|
||||
The following records the earlier source-model migration, **not a prerequisite
|
||||
|
||||
@@ -2,7 +2,7 @@
|
||||
|
||||
Process calibration values live in the version-controlled
|
||||
`config/material-calibrations.yaml`. Calculations refer to opaque IDs; IDs have
|
||||
no special meaning to the parser. The current entry is:
|
||||
no special meaning to the parser. The spreader 1+2 entry is:
|
||||
|
||||
```yaml
|
||||
calibrations:
|
||||
@@ -40,7 +40,7 @@ consumption; the calculation algorithms are unchanged. There is no unit conversi
|
||||
Missing/unreadable files, missing IDs, invalid metadata and incompatible type or
|
||||
unit raise `CalculationConfigError` before a runner starts. Existing direct numeric
|
||||
configurations remain supported; specifying both a reference and a direct factor
|
||||
is rejected. References are currently supported by rotational discharge consumers.
|
||||
is rejected. References are supported by rotational discharge and linear signal application consumers.
|
||||
K7 uses direct mass rate and does not load or require a calibration file.
|
||||
|
||||
## Updating a calibration
|
||||
@@ -67,7 +67,37 @@ On 2026-09-08, an independent gravimetric tray measurement found 4068 g/m² at
|
||||
rounded factor **2.75 kg/(rev*m)**. The original measurement remains recorded,
|
||||
without fitting or adjusting the runtime value to reproduce it exactly.
|
||||
|
||||
Only fresh-bentonite spreaders 1 and 2 are included. Before adding spreader 3,
|
||||
confirm its material scope, actual signal units, independent calibration and
|
||||
whether its output belongs in the fresh-material KPIs. No spreader 3 support is
|
||||
included here.
|
||||
Spreader 3 has an independent entry in the same registry:
|
||||
|
||||
```yaml
|
||||
bento1-spreader-3-bentonite:
|
||||
type: linear_signal_discharge
|
||||
value: 0.4691089108910891
|
||||
unit: kg_per_signal_unit_m
|
||||
calibrated_at: 2026-09-08
|
||||
method: gravimetric_tray
|
||||
description: Bento 1 spreader 3, bentonite
|
||||
reference:
|
||||
measured_application_g_m2: 618
|
||||
signal_value: 3.03
|
||||
line_speed_m_min: 2.3
|
||||
```
|
||||
|
||||
The generic linear consumer requires type `linear_signal_discharge`, unit
|
||||
`kg_per_signal_unit_m`, a positive value, and an explicit calibration reference.
|
||||
It resolves `specific_discharge_kg_per_signal_unit_m`; this runtime field cannot
|
||||
be configured directly as a substitute for the central reference.
|
||||
Calibration measurement: **3.03 signal @ 2.3 m/min → 618 g/m²**.
|
||||
The exact derived discharge factor is `618 * 2.3 / (3.03 * 1000) = 2369/5050`,
|
||||
stored at float precision as **0.4691089108910891 kg/(signal_unit*m)**.
|
||||
The previously supplied approximation 0.4693069307 does not equal that expression.
|
||||
Application is `signal_sum * factor * 1000 / line_speed_m_min`, independent of width.
|
||||
Mass flow is `signal_sum * factor * nominal_width_m` kg/min, independent of speed;
|
||||
the existing kg/h integrator receives this discharge multiplied by 60.
|
||||
|
||||
This measured bentonite calibration does not establish physical units from
|
||||
ENLYZE metadata and must not be used for sand. Spreader 3 may carry sand on other
|
||||
products. Its application, consumption and checkpoints remain separate from
|
||||
fresh-bentonite spreaders 1+2, with no inferred material identity or automatic
|
||||
sum. See [Bento material documentation](bento1-fresh-bentonite.md) for configuration,
|
||||
formulas and operating assumptions.
|
||||
Reference in new issue
Block a user