Add calibrated Bento spreader 3 consumption
This commit is contained in:
1 parent
7ff452d36c
commit
7ff3087775
12 files changed
+485
-31
No files matched your search
@@ -59,6 +59,7 @@ class MaterialCalculationConfig:
|
||||
rotational_speed_signal_refs: tuple[str, ...] = ()
|
||||
specific_discharge_kg_per_rev_m: float | None = None
|
||||
calibration_ref: str | None = None
|
||||
specific_discharge_kg_per_signal_unit_m: float | None = None
|
||||
erp_workplace: str = ""
|
||||
production_order_format: str = ""
|
||||
process_application_calculation_id: str | None = None
|
||||
@@ -92,10 +93,11 @@ def load_material_calculation(
|
||||
raise CalculationConfigError(f"{prefix}.type: only 'material_consumption' is supported")
|
||||
area = entry.get("source_mode", "direct_mass_rate") == "area_application"
|
||||
rotational = entry.get("source_mode") == "rotational_discharge"
|
||||
linear = entry.get("source_mode") == "linear_signal_discharge"
|
||||
if rotational:
|
||||
entry.setdefault("gate_signal_ref", None)
|
||||
entry.setdefault("gate_threshold", 0.0)
|
||||
if area or rotational:
|
||||
if area or rotational or linear:
|
||||
entry.setdefault("rate_signal_ref", "unused")
|
||||
missing = required - entry.keys()
|
||||
if missing:
|
||||
@@ -121,9 +123,10 @@ def load_material_calculation(
|
||||
mode = entry.get("source_mode", "direct_mass_rate")
|
||||
if not isinstance(mode, str) or mode not in {
|
||||
"direct_mass_rate", "area_application", "rotational_discharge",
|
||||
"linear_signal_discharge",
|
||||
}:
|
||||
raise CalculationConfigError("Unsupported material source_mode")
|
||||
if area or rotational:
|
||||
if area or rotational or linear:
|
||||
refs_name = "rotational_speed_signal_refs" if rotational else "application_signal_refs"
|
||||
other = "application_signal_refs" if rotational else "rotational_speed_signal_refs"
|
||||
if other in entry:
|
||||
@@ -152,8 +155,8 @@ def load_material_calculation(
|
||||
)):
|
||||
raise CalculationConfigError("Width context fields require a width-based source mode")
|
||||
if "calibration_ref" in entry:
|
||||
if not rotational:
|
||||
raise CalculationConfigError("calibration_ref requires rotational_discharge")
|
||||
if not (rotational or linear):
|
||||
raise CalculationConfigError("calibration_ref requires a calibrated source mode")
|
||||
if "specific_discharge_kg_per_rev_m" in entry:
|
||||
raise CalculationConfigError(
|
||||
"Specify calibration_ref or direct specific discharge, not both"
|
||||
@@ -166,9 +169,23 @@ def load_material_calculation(
|
||||
calibrations = load_calibrations(Path(path).parent / "material-calibrations.yaml")
|
||||
calibration = resolve_calibration(
|
||||
calibrations, entry["calibration_ref"],
|
||||
expected_type="rotational_discharge", expected_unit="kg_per_rev_m",
|
||||
expected_type=mode,
|
||||
expected_unit="kg_per_signal_unit_m" if linear else "kg_per_rev_m",
|
||||
)
|
||||
entry["specific_discharge_kg_per_rev_m"] = calibration.value
|
||||
factor_name = ("specific_discharge_kg_per_signal_unit_m" if linear
|
||||
else "specific_discharge_kg_per_rev_m")
|
||||
if factor_name in entry:
|
||||
raise CalculationConfigError("Specify calibration_ref only, not a direct factor")
|
||||
entry[factor_name] = calibration.value
|
||||
if linear:
|
||||
if "calibration_ref" not in entry:
|
||||
raise CalculationConfigError("linear_signal_discharge requires calibration_ref")
|
||||
entry["specific_discharge_kg_per_signal_unit_m"] = finite_number(
|
||||
entry["specific_discharge_kg_per_signal_unit_m"],
|
||||
"specific_discharge_kg_per_signal_unit_m", positive=True,
|
||||
)
|
||||
elif "specific_discharge_kg_per_signal_unit_m" in entry:
|
||||
raise CalculationConfigError("Signal discharge factor requires linear_signal_discharge")
|
||||
if rotational:
|
||||
entry["specific_discharge_kg_per_rev_m"] = finite_number(
|
||||
entry.get("specific_discharge_kg_per_rev_m"),
|
||||
@@ -183,9 +200,10 @@ def load_material_calculation(
|
||||
raise CalculationConfigError(
|
||||
"process application ID must be a distinct non-empty string"
|
||||
)
|
||||
if not rotational or not entry["gate_signal_ref"] or entry["gate_threshold"] <= 0:
|
||||
if (not (rotational or linear) or not entry["gate_signal_ref"]
|
||||
or entry["gate_threshold"] <= 0):
|
||||
raise CalculationConfigError(
|
||||
"Process application requires rotational_discharge and a positive speed gate"
|
||||
"Process application requires a calibrated source and a positive speed gate"
|
||||
)
|
||||
if entry["id"] in instances:
|
||||
raise CalculationConfigError("Calculation ids must be unique")
|
||||
|
||||
@@ -1,4 +1,4 @@
|
||||
"""Width-independent process application from actual rotational speeds."""
|
||||
"""Width-independent process application from calibrated source signals."""
|
||||
|
||||
from collections.abc import Iterable
|
||||
from math import isfinite
|
||||
@@ -23,3 +23,15 @@ def rotational_application_g_m2(
|
||||
if not isfinite(value):
|
||||
raise ValueError("derived application must be finite")
|
||||
return value
|
||||
|
||||
|
||||
|
||||
def linear_signal_discharge_g_m2(
|
||||
signal_values: Iterable[float], specific_discharge_kg_per_signal_unit_m: float,
|
||||
line_speed_m_min: float, gate_threshold: float,
|
||||
) -> float | None:
|
||||
"""Derive speed-normalized application from calibrated signal discharge."""
|
||||
return rotational_application_g_m2(
|
||||
signal_values, specific_discharge_kg_per_signal_unit_m,
|
||||
line_speed_m_min, gate_threshold,
|
||||
)
|
||||
@@ -138,3 +138,13 @@ def rotational_discharge_rate_kg_per_hour(
|
||||
if not isfinite(rate):
|
||||
raise ValueError("derived material rate must be finite")
|
||||
return rate
|
||||
|
||||
|
||||
def linear_signal_discharge_rate_kg_per_hour(
|
||||
signal_values: Iterable[float], nominal_width_m: float,
|
||||
specific_discharge_kg_per_signal_unit_m: float,
|
||||
) -> float:
|
||||
"""Convert calibrated signal discharge to kg/h, independently of line speed."""
|
||||
return rotational_discharge_rate_kg_per_hour(
|
||||
signal_values, nominal_width_m, specific_discharge_kg_per_signal_unit_m,
|
||||
)
|
||||
@@ -165,6 +165,7 @@ class EnlyzeApiGateway:
|
||||
rotational_speed_variable_ids: tuple[str, ...] = (),
|
||||
specific_discharge_kg_per_rev_m: float | None = None,
|
||||
process_application_gate_threshold: float | None = None,
|
||||
specific_discharge_kg_per_signal_unit_m: float | None = None,
|
||||
) -> list[MaterialSample]:
|
||||
for name, value in (("start", start), ("end", end)):
|
||||
if value.tzinfo is None or value.utcoffset() is None:
|
||||
@@ -175,6 +176,8 @@ class EnlyzeApiGateway:
|
||||
raise ValueError("Material source modes are mutually exclusive")
|
||||
if gate_variable_id is None and not rotational_speed_variable_ids:
|
||||
raise ValueError("This source requires a gate signal")
|
||||
if specific_discharge_kg_per_signal_unit_m is not None and not application_variable_ids:
|
||||
raise ValueError("Signal discharge requires source signals")
|
||||
source_ids = (
|
||||
rotational_speed_variable_ids or application_variable_ids or (rate_variable_id,)
|
||||
)
|
||||
@@ -223,6 +226,16 @@ class EnlyzeApiGateway:
|
||||
nominal_width_m,
|
||||
specific_discharge_kg_per_rev_m,
|
||||
)
|
||||
elif specific_discharge_kg_per_signal_unit_m is not None:
|
||||
from production_analytics.calculations.material_consumption import (
|
||||
linear_signal_discharge_rate_kg_per_hour,
|
||||
)
|
||||
|
||||
if nominal_width_m is None:
|
||||
raise ValueError("signal discharge requires nominal width")
|
||||
rate = linear_signal_discharge_rate_kg_per_hour(
|
||||
sources, nominal_width_m, specific_discharge_kg_per_signal_unit_m,
|
||||
)
|
||||
elif application_variable_ids:
|
||||
if nominal_width_m is None:
|
||||
raise ValueError("area application requires nominal width")
|
||||
@@ -231,18 +244,30 @@ class EnlyzeApiGateway:
|
||||
rate = sources[0]
|
||||
application = None
|
||||
if process_application_gate_threshold is not None:
|
||||
if not rotational_speed_variable_ids or gate_variable_id is None:
|
||||
raise ValueError("Process application requires rpm and speed gate")
|
||||
if specific_discharge_kg_per_signal_unit_m is not None:
|
||||
from production_analytics.calculations.material_application import (
|
||||
linear_signal_discharge_g_m2,
|
||||
)
|
||||
|
||||
application = linear_signal_discharge_g_m2(
|
||||
sources, specific_discharge_kg_per_signal_unit_m,
|
||||
gate, process_application_gate_threshold,
|
||||
)
|
||||
elif not rotational_speed_variable_ids or gate_variable_id is None:
|
||||
raise ValueError(
|
||||
"Process application requires discharge and speed gate"
|
||||
)
|
||||
from production_analytics.calculations.material_application import (
|
||||
rotational_application_g_m2,
|
||||
)
|
||||
|
||||
application = rotational_application_g_m2(
|
||||
sources,
|
||||
specific_discharge_kg_per_rev_m,
|
||||
gate,
|
||||
process_application_gate_threshold,
|
||||
)
|
||||
if rotational_speed_variable_ids:
|
||||
application = rotational_application_g_m2(
|
||||
sources,
|
||||
specific_discharge_kg_per_rev_m,
|
||||
gate,
|
||||
process_application_gate_threshold,
|
||||
)
|
||||
samples.append(
|
||||
MaterialSample(
|
||||
timestamp=_parse_timestamp(record[time_index]),
|
||||
|
||||
@@ -61,15 +61,21 @@ class MaterialPollingService:
|
||||
nominal_width_provider: Callable[[str], float] | None = None,
|
||||
process_application_calculation_id: str | None = None,
|
||||
application_writer: MaterialApplicationWriter | None = None,
|
||||
specific_discharge_kg_per_signal_unit_m: float | None = None,
|
||||
) -> None:
|
||||
if application_variable_ids and rotational_speed_variable_ids:
|
||||
raise ValueError("Material source modes are mutually exclusive")
|
||||
if specific_discharge_kg_per_signal_unit_m is not None and not application_variable_ids:
|
||||
raise ValueError("Signal discharge requires source signals")
|
||||
self._signal_discharge = specific_discharge_kg_per_signal_unit_m
|
||||
if process_application_calculation_id is not None and (
|
||||
not rotational_speed_variable_ids or not gate_variable_id
|
||||
not (rotational_speed_variable_ids
|
||||
or specific_discharge_kg_per_signal_unit_m is not None)
|
||||
or not gate_variable_id
|
||||
or gate_threshold <= 0 or application_writer is None
|
||||
):
|
||||
raise ValueError(
|
||||
"Process application requires rotational source, positive gate and writer"
|
||||
"Process application requires calibrated source, positive gate and writer"
|
||||
)
|
||||
self._process_application_calculation_id = process_application_calculation_id
|
||||
self._application_writer = application_writer
|
||||
@@ -171,6 +177,8 @@ class MaterialPollingService:
|
||||
source_options = dict(
|
||||
application_variable_ids=self._application_variable_ids, nominal_width_m=width,
|
||||
)
|
||||
if self._signal_discharge is not None:
|
||||
source_options["specific_discharge_kg_per_signal_unit_m"] = self._signal_discharge
|
||||
if self._rotational_speed_variable_ids:
|
||||
source_options = dict(
|
||||
rotational_speed_variable_ids=self._rotational_speed_variable_ids,
|
||||
|
||||
@@ -3,6 +3,7 @@
|
||||
import math
|
||||
import os
|
||||
import tempfile
|
||||
from hashlib import sha256
|
||||
from pathlib import Path
|
||||
from urllib.parse import urlsplit
|
||||
|
||||
@@ -76,7 +77,9 @@ def build_material_runner(
|
||||
) from exc
|
||||
postgres_settings = PostgresSettings.from_environment(environment)
|
||||
source_options = {}
|
||||
if calculation.source_mode in {"area_application", "rotational_discharge"}:
|
||||
if calculation.source_mode in {
|
||||
"area_application", "rotational_discharge", "linear_signal_discharge",
|
||||
}:
|
||||
source_options = dict(
|
||||
application_variable_ids=calculation.application_signal_refs,
|
||||
nominal_width_provider=ErpNominalWidthProvider(
|
||||
@@ -85,6 +88,12 @@ def build_material_runner(
|
||||
format_template=calculation.production_order_format,
|
||||
),
|
||||
)
|
||||
if calculation.source_mode == "linear_signal_discharge":
|
||||
source_options["specific_discharge_kg_per_signal_unit_m"] = (
|
||||
calculation.specific_discharge_kg_per_signal_unit_m
|
||||
)
|
||||
# Legacy runners retain their checkpoints; new calibrated sources are isolated.
|
||||
state_directory = state_directory / sha256(calculation.id.encode("utf-8")).hexdigest()
|
||||
if calculation.source_mode == "rotational_discharge":
|
||||
source_options.pop("application_variable_ids")
|
||||
source_options.update(
|
||||
|
||||
Reference in new issue
Block a user