Document Bento spreader 3 deployment

This commit is contained in:
admin committed 2026-10-02 20:39:45 +02:00
1 parent 7ff3087775
commit c0d1c0aa79
4 files changed
+159 -63

No files matched your search

+3 -3
View File
@@ -40,7 +40,7 @@ consumption; the calculation algorithms are unchanged. There is no unit conversi
Missing/unreadable files, missing IDs, invalid metadata and incompatible type or
unit raise `CalculationConfigError` before a runner starts. Existing direct numeric
configurations remain supported; specifying both a reference and a direct factor
is rejected. References are supported by rotational discharge and linear signal application consumers.
is rejected. References are supported by rotational discharge and `linear_signal_discharge` consumers.
K7 uses direct mass rate and does not load or require a calibration file.
## Updating a calibration
@@ -90,13 +90,13 @@ be configured directly as a substitute for the central reference.
Calibration measurement: **3.03 signal @ 2.3 m/min → 618 g/m²**.
The exact derived discharge factor is `618 * 2.3 / (3.03 * 1000) = 2369/5050`,
stored at float precision as **0.4691089108910891 kg/(signal_unit*m)**.
The previously supplied approximation 0.4693069307 does not equal that expression.
Application is `signal_sum * factor * 1000 / line_speed_m_min`, independent of width.
Mass flow is `signal_sum * factor * nominal_width_m` kg/min, independent of speed;
the existing kg/h integrator receives this discharge multiplied by 60.
This measured bentonite calibration does not establish physical units from
ENLYZE metadata and must not be used for sand. Spreader 3 may carry sand on other
ENLYZE metadata and must not be used for sand. Sand calibration is intentionally
not implemented yet. Spreader 3 may carry sand on other
products. Its application, consumption and checkpoints remain separate from
fresh-bentonite spreaders 1+2, with no inferred material identity or automatic
sum. See [Bento material documentation](bento1-fresh-bentonite.md) for configuration,