Fix power meter CLI error handling
This commit is contained in:
@@ -260,6 +260,7 @@ def _parse_cli_timestamp(value: str) -> object:
|
|||||||
def _run_power_meter(args: argparse.Namespace) -> int:
|
def _run_power_meter(args: argparse.Namespace) -> int:
|
||||||
from datetime import UTC, datetime, timedelta
|
from datetime import UTC, datetime, timedelta
|
||||||
import time
|
import time
|
||||||
|
from production_analytics.calculations.config import CalculationConfigError
|
||||||
from production_analytics.enlyze.exploration import ConfigurationError
|
from production_analytics.enlyze.exploration import ConfigurationError
|
||||||
from production_analytics.power_meter.config import load_power_meter_config
|
from production_analytics.power_meter.config import load_power_meter_config
|
||||||
from production_analytics.power_meter.gateway import PowerMeterGateway
|
from production_analytics.power_meter.gateway import PowerMeterGateway
|
||||||
|
|||||||
+16
-1
@@ -3,7 +3,7 @@ import json
|
|||||||
import os
|
import os
|
||||||
import tempfile
|
import tempfile
|
||||||
import unittest
|
import unittest
|
||||||
from contextlib import redirect_stdout
|
from contextlib import redirect_stderr, redirect_stdout
|
||||||
from pathlib import Path
|
from pathlib import Path
|
||||||
from unittest.mock import patch
|
from unittest.mock import patch
|
||||||
|
|
||||||
@@ -12,6 +12,21 @@ from production_analytics.enlyze.exploration import ExplorationResponse
|
|||||||
|
|
||||||
|
|
||||||
class CliTests(unittest.TestCase):
|
class CliTests(unittest.TestCase):
|
||||||
|
def test_power_meter_config_error_returns_controlled_exit_code(self) -> None:
|
||||||
|
with tempfile.TemporaryDirectory() as temporary_directory:
|
||||||
|
missing_config = Path(temporary_directory) / "missing.yaml"
|
||||||
|
error_output = io.StringIO()
|
||||||
|
with redirect_stderr(error_output):
|
||||||
|
result = main([
|
||||||
|
"run", "power-meter", "--config", str(missing_config), "--meter", "B2",
|
||||||
|
"--start", "2026-10-01T10:00:00Z", "--end", "2026-10-01T10:10:00Z",
|
||||||
|
])
|
||||||
|
|
||||||
|
self.assertEqual(result, 2)
|
||||||
|
self.assertIn(
|
||||||
|
"Config/startup error: Cannot read power-meter configuration", error_output.getvalue()
|
||||||
|
)
|
||||||
|
|
||||||
@patch.dict(os.environ, {"ENLYZE_BASE_URL": "https://enlyze.example"}, clear=True)
|
@patch.dict(os.environ, {"ENLYZE_BASE_URL": "https://enlyze.example"}, clear=True)
|
||||||
@patch("production_analytics.cli.__main__.ExplorationClient.get")
|
@patch("production_analytics.cli.__main__.ExplorationClient.get")
|
||||||
def test_raw_prints_and_saves_sanitized_response(self, get_mock: object) -> None:
|
def test_raw_prints_and_saves_sanitized_response(self, get_mock: object) -> None:
|
||||||
|
|||||||
Reference in New Issue