# Shift running-speed KPI `average_line_speed_m_min` is the arithmetic mean of active, finite production-speed samples in `[start, end)`. Each active sample has equal weight. The calculation does not interpolate or weight speed by elapsed time. ## Activity gates The `speed` block has exactly one activity method: - **Simple numeric:** `production_gate_m_min` selects speed samples strictly above the threshold. B1, E1 and K7 retain this behavior. - **Boolean:** `running_signal_ref` and optional `running_when` (default `true`) select samples whose status is exactly that Boolean. K5 uses `running_when: false` because its status signal is true when stopped. - **Numeric dwell:** `numeric_dwell_gate` has `signal_ref`, finite `threshold`, `comparison` (`below` or `above`), and positive integer `minimum_duration_seconds`. Gitter 1–4 use `below` and 150 seconds. Their production-speed signal holds its last value while stopped, and their PLC Boolean status did not reliably indicate downtime. The numeric gate follows the configured ENLYZE threshold and minimum duration concept. For `below`, only a gate value strictly less than the threshold satisfies the condition. An equal value ends a below-threshold run. Rows are ordered by their UTC timestamps; a condition reading remains the observed state until the next reading. A continuous below-threshold run qualifies when the elapsed time from its first below-threshold timestamp to the first non-below reading is at least the minimum duration. If it qualifies, **all** speed samples in that run are inactive, including those before the minimum duration elapsed. A short run bracketed by non-below readings stays active. The same rules apply to `above`. The interval ending at the non-satisfying reading excludes that reading. The service requests speed and the gate signal together from `/v2/timeseries`. For a dwell gate it extends the read window by one minimum duration on each side; only production-speed samples in the original report window enter the KPI. This lets a qualifying run crossing a report boundary be classified when the source provides enough surrounding readings. An unclosed short run, or a short run without a preceding non-satisfying reading, has unknown duration and is excluded conservatively. An invalid or non-finite gate reading breaks continuity and its speed row is excluded. A missing required gate column fails the read. No absent rows are synthesized; the result depends on the timestamps returned by ENLYZE, which deserves validation against live boundary cases. Invalid speed values (including Boolean, null, non-numeric, NaN, and infinity) are excluded in every mode. Invalid timestamps are also excluded. In Boolean mode, missing or non-Boolean status is excluded. `sample_count` is the sum of active and inactive valid speed samples; excluded samples increment `invalid_sample_count`. If no active samples remain, average, minimum and maximum are `None`. Machine UUIDs and gate settings live in `config/shift-report-machines.yaml`. The loader validates the gate fields and rejects overlapping Boolean and dwell gates. `ShiftSpeedService.summarize()` composes the gateway read with the pure `aggregate_shift_speed()` calculation. The calculation accepts `ShiftSpeedSample(timestamp, value, running, gate_value)` records. Structural timeseries and pagination errors fail the read instead of returning a partial KPI. ## Supplied legacy reference For 2026-10-07 06:00–14:00 Europe/Berlin: | Machine | Samples | Active samples | Active average (m/min) | | --- | ---: | ---: | ---: | | B1 | 2880 | 1603 | 2.3139663284001912 | | E1 | 2880 | 2782 | 7.933009468249328 | | K7 | 2880 | 2667 | 10.078945039942955 | These are supplied validation values, not a new live read.