# Material calibrations
|
||
|
||
Process calibration values live in the version-controlled
|
||
`config/material-calibrations.yaml`. Calculations refer to opaque IDs; IDs have
|
||
no special meaning to the parser. The spreader 1+2 entry is:
|
||
|
||
```yaml
|
||
calibrations:
|
||
bento1-spreader-1-2:
|
||
type: rotational_discharge
|
||
value: 2.75
|
||
unit: kg_per_rev_m
|
||
calibrated_at: 2026-09-08
|
||
method: gravimetric_tray
|
||
description: Bento 1 fresh-bentonite spreaders 1 and 2
|
||
reference:
|
||
measured_application_g_m2: 4068
|
||
line_speed_m_min: 2.3
|
||
signal_values:
|
||
left: 1.65
|
||
right: 1.75
|
||
```
|
||
|
||
All entry fields are required. Type, unit, method and description are non-empty
|
||
strings; value must be a finite number (booleans are rejected); calibrated_at is
|
||
a calendar date in YYYY-MM-DD format, quoted or unquoted. Reference is a non-empty
|
||
mapping whose contents preserve source-specific measurement provenance. Unknown
|
||
entry fields and duplicate YAML keys are rejected. The generic registry permits
|
||
other types and units; each consuming calculation checks its own compatibility.
|
||
|
||
`config/bento1-material-consumption.yaml` contains
|
||
`calibration_ref: bento1-spreader-1-2`. During configuration loading, references
|
||
resolve from `material-calibrations.yaml` in the calculation file's directory,
|
||
independently of the working directory. The entire registry is validated when a
|
||
reference is used. Rotational discharge requires type `rotational_discharge`,
|
||
unit `kg_per_rev_m` and a positive value. Resolution supplies the existing
|
||
`specific_discharge_kg_per_rev_m` runtime field for both application and
|
||
consumption; the calculation algorithms are unchanged. There is no unit conversion.
|
||
|
||
Missing/unreadable files, missing IDs, invalid metadata and incompatible type or
|
||
unit raise `CalculationConfigError` before a runner starts. Existing direct numeric
|
||
configurations remain supported; specifying both a reference and a direct factor
|
||
is rejected. References are supported by rotational discharge and `linear_signal_discharge` consumers.
|
||
K7 uses direct mass rate and does not load or require a calibration file.
|
||
|
||
## Updating a calibration
|
||
|
||
After a physical measurement, edit only the central entry's value, date, method
|
||
and reference details, and keep its ID stable. Review and version-control the
|
||
change. Additional machines can add new IDs using the same structure. A new
|
||
calculation type needs an explicit consumer compatibility contract.
|
||
|
||
Ship the central YAML alongside the calculation YAML and restart the consuming
|
||
process to load changes. No new CLI flag, environment variable, database migration
|
||
or UI is required. There is no hot reload or historical date-based selection.
|
||
Changes affect future calculations and explicitly rebuilt calculations. Historical
|
||
persisted snapshots are **not automatically recalculated**. Existing checkpoints
|
||
retain accumulated totals, so subsequent increments use the newly loaded factor;
|
||
a complete historical rebuild requires a separately planned replay. Persisted
|
||
snapshots do not gain calibration-version provenance through this change.
|
||
|
||
## Current Bento provenance
|
||
|
||
On 2026-09-08, an independent gravimetric tray measurement found 4068 g/m² at
|
||
2.3 m/min with actual rotational signals left 1.65 and right 1.75.
|
||
`(4068 / 1000) × 2.3 / (1.65 + 1.75) ≈ 2.75188 kg/(rev*m)` gives the configured
|
||
rounded factor **2.75 kg/(rev*m)**. The original measurement remains recorded,
|
||
without fitting or adjusting the runtime value to reproduce it exactly.
|
||
|
||
Spreader 3 has an independent entry in the same registry:
|
||
|
||
```yaml
|
||
bento1-spreader-3-bentonite:
|
||
type: linear_signal_discharge
|
||
value: 0.4691089108910891
|
||
unit: kg_per_signal_unit_m
|
||
calibrated_at: 2026-09-08
|
||
method: gravimetric_tray
|
||
description: Bento 1 spreader 3, bentonite
|
||
reference:
|
||
measured_application_g_m2: 618
|
||
signal_value: 3.03
|
||
line_speed_m_min: 2.3
|
||
```
|
||
|
||
The generic linear consumer requires type `linear_signal_discharge`, unit
|
||
`kg_per_signal_unit_m`, a positive value, and an explicit calibration reference.
|
||
It resolves `specific_discharge_kg_per_signal_unit_m`; this runtime field cannot
|
||
be configured directly as a substitute for the central reference.
|
||
Calibration measurement: **3.03 signal @ 2.3 m/min → 618 g/m²**.
|
||
The exact derived discharge factor is `618 * 2.3 / (3.03 * 1000) = 2369/5050`,
|
||
stored at float precision as **0.4691089108910891 kg/(signal_unit*m)**.
|
||
Application is `signal_sum * factor * 1000 / line_speed_m_min`, independent of width.
|
||
Mass flow is `signal_sum * factor * nominal_width_m` kg/min, independent of speed;
|
||
the existing kg/h integrator receives this discharge multiplied by 60.
|
||
|
||
This measured bentonite calibration does not establish physical units from
|
||
ENLYZE metadata and must not be used for sand. Sand calibration is intentionally
|
||
not implemented yet. Spreader 3 may carry sand on other
|
||
products. Its application, consumption and checkpoints remain separate from
|
||
fresh-bentonite spreaders 1+2, with no inferred material identity or automatic
|
||
sum. See [Bento material documentation](bento1-fresh-bentonite.md) for configuration,
|
||
formulas and operating assumptions.
|