# Shift running-speed KPI
|
||
|
||
`average_line_speed_m_min` is the arithmetic mean of active, finite production-speed
|
||
samples in `[start, end)`. Each active sample has equal weight. The calculation does
|
||
not interpolate or weight speed by elapsed time.
|
||
|
||
## Activity gates
|
||
|
||
The `speed` block has exactly one activity method:
|
||
|
||
- **Simple numeric:** `production_gate_m_min` selects speed samples strictly above
|
||
the threshold. B1, E1 and K7 retain this behavior.
|
||
- **Boolean:** `running_signal_ref` and optional `running_when` (default `true`)
|
||
select samples whose status is exactly that Boolean. K5 uses `running_when: false`
|
||
because its status signal is true when stopped.
|
||
- **Numeric dwell:** `numeric_dwell_gate` has `signal_ref`, finite `threshold`,
|
||
`comparison` (`below` or `above`), and positive integer
|
||
`minimum_duration_seconds`. Gitter 1–4 use `below` and 150 seconds. Their
|
||
production-speed signal holds its last value while stopped, and their PLC
|
||
Boolean status did not reliably indicate downtime. The numeric gate follows
|
||
the configured ENLYZE threshold and minimum duration concept.
|
||
|
||
For `below`, only a gate value strictly less than the threshold satisfies the
|
||
condition. An equal value ends a below-threshold run. Rows are ordered by their
|
||
UTC timestamps; a condition reading remains the observed state until the next
|
||
reading. A continuous below-threshold run qualifies when the elapsed time from
|
||
its first below-threshold timestamp to the first non-below reading is at least
|
||
the minimum duration. If it qualifies, **all** speed samples in that run are
|
||
inactive, including those before the minimum duration elapsed. A short run
|
||
bracketed by non-below readings stays active. The same rules apply to `above`.
|
||
The interval ending at the non-satisfying reading excludes that reading.
|
||
|
||
The service requests speed and the gate signal together from `/v2/timeseries`.
|
||
For a dwell gate it extends the read window by one minimum duration on each side;
|
||
only production-speed samples in the original report window enter the KPI. This
|
||
lets a qualifying run crossing a report boundary be classified when the source
|
||
provides enough surrounding readings. An unclosed short run, or a short run
|
||
without a preceding non-satisfying reading, has unknown duration and is excluded
|
||
conservatively. An invalid or non-finite gate reading breaks continuity and its
|
||
speed row is excluded. A missing required gate column fails the read. No absent
|
||
rows are synthesized; the result depends on the timestamps returned by ENLYZE,
|
||
which deserves validation against live boundary cases.
|
||
|
||
Invalid speed values (including Boolean, null, non-numeric, NaN, and infinity)
|
||
are excluded in every mode. Invalid timestamps are also excluded. In Boolean
|
||
mode, missing or non-Boolean status is excluded. `sample_count` is the sum of
|
||
active and inactive valid speed samples; excluded samples increment
|
||
`invalid_sample_count`. If no active samples remain, average, minimum and maximum
|
||
are `None`.
|
||
|
||
Machine UUIDs and gate settings live in `config/shift-report-machines.yaml`.
|
||
The loader validates the gate fields and rejects overlapping Boolean and dwell
|
||
gates. `ShiftSpeedService.summarize()` composes the gateway read with the pure
|
||
`aggregate_shift_speed()` calculation. The calculation accepts
|
||
`ShiftSpeedSample(timestamp, value, running, gate_value)` records. Structural
|
||
timeseries and pagination errors fail the read instead of returning a partial KPI.
|
||
|
||
## Supplied legacy reference
|
||
|
||
For 2026-10-07 06:00–14:00 Europe/Berlin:
|
||
|
||
| Machine | Samples | Active samples | Active average (m/min) |
|
||
| --- | ---: | ---: | ---: |
|
||
| B1 | 2880 | 1603 | 2.3139663284001912 |
|
||
| E1 | 2880 | 2782 | 7.933009468249328 |
|
||
| K7 | 2880 | 2667 | 10.078945039942955 |
|
||
|
||
These are supplied validation values, not a new live read.
|