3.7 KiB
Shift running-speed KPI
average_line_speed_m_min is the arithmetic mean of active, finite production-speed
samples in [start, end). Each active sample has equal weight. The calculation does
not interpolate or weight speed by elapsed time.
Activity gates
The speed block has exactly one activity method:
- Simple numeric:
production_gate_m_minselects speed samples strictly above the threshold. B1, E1 and K7 retain this behavior. - Boolean:
running_signal_refand optionalrunning_when(defaulttrue) select samples whose status is exactly that Boolean. K5 usesrunning_when: falsebecause its status signal is true when stopped. - Numeric dwell:
numeric_dwell_gatehassignal_ref, finitethreshold,comparison(beloworabove), and positive integerminimum_duration_seconds. Gitter 1–4 usebelowand 150 seconds. Their production-speed signal holds its last value while stopped, and their PLC Boolean status did not reliably indicate downtime. The numeric gate follows the configured ENLYZE threshold and minimum duration concept.
For below, only a gate value strictly less than the threshold satisfies the
condition. An equal value ends a below-threshold run. Rows are ordered by their
UTC timestamps; a condition reading remains the observed state until the next
reading. A continuous below-threshold run qualifies when the elapsed time from
its first below-threshold timestamp to the first non-below reading is at least
the minimum duration. If it qualifies, all speed samples in that run are
inactive, including those before the minimum duration elapsed. A short run
bracketed by non-below readings stays active. The same rules apply to above.
The interval ending at the non-satisfying reading excludes that reading.
The service requests speed and the gate signal together from /v2/timeseries.
For a dwell gate it extends the read window by one minimum duration on each side;
only production-speed samples in the original report window enter the KPI. This
lets a qualifying run crossing a report boundary be classified when the source
provides enough surrounding readings. An unclosed short run, or a short run
without a preceding non-satisfying reading, has unknown duration and is excluded
conservatively. An invalid or non-finite gate reading breaks continuity and its
speed row is excluded. A missing required gate column fails the read. No absent
rows are synthesized; the result depends on the timestamps returned by ENLYZE,
which deserves validation against live boundary cases.
Invalid speed values (including Boolean, null, non-numeric, NaN, and infinity)
are excluded in every mode. Invalid timestamps are also excluded. In Boolean
mode, missing or non-Boolean status is excluded. sample_count is the sum of
active and inactive valid speed samples; excluded samples increment
invalid_sample_count. If no active samples remain, average, minimum and maximum
are None.
Machine UUIDs and gate settings live in config/shift-report-machines.yaml.
The loader validates the gate fields and rejects overlapping Boolean and dwell
gates. ShiftSpeedService.summarize() composes the gateway read with the pure
aggregate_shift_speed() calculation. The calculation accepts
ShiftSpeedSample(timestamp, value, running, gate_value) records. Structural
timeseries and pagination errors fail the read instead of returning a partial KPI.
Supplied legacy reference
For 2026-10-07 06:00–14:00 Europe/Berlin:
| Machine | Samples | Active samples | Active average (m/min) |
|---|---|---|---|
| B1 | 2880 | 1603 | 2.3139663284001912 |
| E1 | 2880 | 2782 | 7.933009468249328 |
| K7 | 2880 | 2667 | 10.078945039942955 |
These are supplied validation values, not a new live read.