# Material calibrations
Process calibration values live in the version-controlled
`config/material-calibrations.yaml`. Calculations refer to opaque IDs; IDs have
no special meaning to the parser. The spreader 1+2 entry is:
```yaml
calibrations:
bento1-spreader-1-2:
type: rotational_discharge
value: 2.75
unit: kg_per_rev_m
calibrated_at: 2026-09-08
method: gravimetric_tray
description: Bento 1 fresh-bentonite spreaders 1 and 2
reference:
measured_application_g_m2: 4068
line_speed_m_min: 2.3
signal_values:
left: 1.65
right: 1.75
```
All entry fields are required. Type, unit, method and description are non-empty
strings; value must be a finite number (booleans are rejected); calibrated_at is
a calendar date in YYYY-MM-DD format, quoted or unquoted. Reference is a non-empty
mapping whose contents preserve source-specific measurement provenance. Unknown
entry fields and duplicate YAML keys are rejected. The generic registry permits
other types and units; each consuming calculation checks its own compatibility.
`config/bento1-material-consumption.yaml` contains
`calibration_ref: bento1-spreader-1-2`. During configuration loading, references
resolve from `material-calibrations.yaml` in the calculation file's directory,
independently of the working directory. The entire registry is validated when a
reference is used. Rotational discharge requires type `rotational_discharge`,
unit `kg_per_rev_m` and a positive value. Resolution supplies the existing
`specific_discharge_kg_per_rev_m` runtime field for both application and
consumption; the calculation algorithms are unchanged. There is no unit conversion.
Missing/unreadable files, missing IDs, invalid metadata and incompatible type or
unit raise `CalculationConfigError` before a runner starts. Existing direct numeric
configurations remain supported; specifying both a reference and a direct factor
is rejected. References are supported by rotational discharge and linear signal application consumers.
K7 uses direct mass rate and does not load or require a calibration file.
## Updating a calibration
After a physical measurement, edit only the central entry's value, date, method
and reference details, and keep its ID stable. Review and version-control the
change. Additional machines can add new IDs using the same structure. A new
calculation type needs an explicit consumer compatibility contract.
Ship the central YAML alongside the calculation YAML and restart the consuming
process to load changes. No new CLI flag, environment variable, database migration
or UI is required. There is no hot reload or historical date-based selection.
Changes affect future calculations and explicitly rebuilt calculations. Historical
persisted snapshots are **not automatically recalculated**. Existing checkpoints
retain accumulated totals, so subsequent increments use the newly loaded factor;
a complete historical rebuild requires a separately planned replay. Persisted
snapshots do not gain calibration-version provenance through this change.
## Current Bento provenance
On 2026-09-08, an independent gravimetric tray measurement found 4068 g/m² at
2.3 m/min with actual rotational signals left 1.65 and right 1.75.
`(4068 / 1000) × 2.3 / (1.65 + 1.75) ≈ 2.75188 kg/(rev*m)` gives the configured
rounded factor **2.75 kg/(rev*m)**. The original measurement remains recorded,
without fitting or adjusting the runtime value to reproduce it exactly.
Spreader 3 has an independent entry in the same registry:
```yaml
bento1-spreader-3-bentonite:
type: linear_signal_discharge
value: 0.4691089108910891
unit: kg_per_signal_unit_m
calibrated_at: 2026-09-08
method: gravimetric_tray
description: Bento 1 spreader 3, bentonite
reference:
measured_application_g_m2: 618
signal_value: 3.03
line_speed_m_min: 2.3
```
The generic linear consumer requires type `linear_signal_discharge`, unit
`kg_per_signal_unit_m`, a positive value, and an explicit calibration reference.
It resolves `specific_discharge_kg_per_signal_unit_m`; this runtime field cannot
be configured directly as a substitute for the central reference.
Calibration measurement: **3.03 signal @ 2.3 m/min → 618 g/m²**.
The exact derived discharge factor is `618 * 2.3 / (3.03 * 1000) = 2369/5050`,
stored at float precision as **0.4691089108910891 kg/(signal_unit*m)**.
The previously supplied approximation 0.4693069307 does not equal that expression.
Application is `signal_sum * factor * 1000 / line_speed_m_min`, independent of width.
Mass flow is `signal_sum * factor * nominal_width_m` kg/min, independent of speed;
the existing kg/h integrator receives this discharge multiplied by 60.
This measured bentonite calibration does not establish physical units from
ENLYZE metadata and must not be used for sand. Spreader 3 may carry sand on other
products. Its application, consumption and checkpoints remain separate from
fresh-bentonite spreaders 1+2, with no inferred material identity or automatic
sum. See [Bento material documentation](bento1-fresh-bentonite.md) for configuration,
formulas and operating assumptions.