Files
production-analytics/tests/test_power_meter.py
T

45 lines
1.9 KiB
Python

from datetime import UTC, datetime
from unittest.mock import Mock
import pytest
from production_analytics.power_meter.config import load_power_meter_config
from production_analytics.power_meter.gateway import PowerMeterGateway
from production_analytics.power_meter.repository import counter_delta
def test_b2_config_has_only_verified_signals() -> None:
config = load_power_meter_config("config/power-meters.example.yaml", "B2")
assert config.machine_uuid == "0d7955e9-5cde-4e14-9af7-5b041dc796f0"
assert config.signals.energy_total == "0f5c0853-1aa7-4fa3-b267-ea2669024e46"
assert config.signals.power_outages is None
def test_counter_reset_starts_new_epoch() -> None:
assert counter_delta(None, 7) == 0
assert counter_delta(100, 105) == 5
assert counter_delta(100, 4) == 4
def test_gateway_keeps_optional_phases_and_handles_pagination() -> None:
config = load_meter()
client = Mock()
client.post_json.side_effect = [
Mock(body={"data": {"columns": ["time", "e", "p", "f", "l1"],
"records": [["2026-09-01T00:00:00Z", 10, 4, 50, 2]]},
"metadata": {"next_cursor": "next"}}),
Mock(body={"data": {"columns": ["time", "e", "p", "f", "l1"],
"records": [["2026-09-01T00:01:00Z", 11, 5, 49.9, 3]]},
"metadata": {"next_cursor": None}}),
]
readings = PowerMeterGateway(client).read(config, datetime(2026, 9, 1, tzinfo=UTC),
datetime(2026, 9, 2, tzinfo=UTC))
assert [item.energy_total_kwh for item in readings] == [10, 11]
assert readings[0].phase_active_power_kw == (("L1", 2.0),)
assert client.post_json.call_args_list[1].args[1]["cursor"] == "next"
def load_meter():
from production_analytics.power_meter.config import PowerMeterConfig, PowerMeterSignals
return PowerMeterConfig("B2", "machine", PowerMeterSignals("e", "p", "f", phase_active_power=(("L1", "l1"),)))